Power supplies
The S5200F-ON Series (S5232F-ON, S5248F-ON, S5296F-ON, S5224F-ON, or S5212F-ON) switch ships with two AC or DC power
supplies. The two power supplies have two air-ow directions—from the I/O to the PSU and from the PSU to the I/O.
Two PSUs are required for full redundancy, but the switch can operate with a single PSU.
For all switches except the S5212F-ON switch, the PSUs are eld replaceable. When running with full redundancy—two power supplies
installed and running—you can remove and replace one PSU without disrupting trac. For the S5212F-ON switch, the PSUs are xed.
CAUTION: To prevent electrical shock, ensure that the S5200F-ON Series switch is grounded properly. If you do not ground your
equipment correctly, excessive emissions may result. Use a qualied electrician to ensure that the power cables meet your local
electrical requirements.
NOTE: NOTE: Connect the power supply to the appropriate branch circuit protection as dened by your local electrical codes.
Verify that the remote power source complies with the switch input power specications.
NOTE: If you use a single PSU, install a blank plate in the other PSU slot. Use power supply 2 (PSU2) as the blank plate slot. To
install the blank plate, use a #1 Philips screw driver.
NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when
handling the S5200F-ON Series switch and components.
Topics:
Components
AC or DC power supply installation
Power cable clip installation
Components
The following power supply options are available for the S5200F-ON Series switch:
AC or DC power supply with integrated fan
AC or DC power supply with integrated reverse ow fan, except S5212F-ON
S5212F-ON only: AC or DC open-frame power supply without integrated fans
For the S5224F-ON, S5232F-ON, and S5248F-ON switches, power supply 1 (PSU1) is on the left side of the switch; power supply 2
(PSU2) is on the right side of the switch. For the S5212F-ON and S5296F-ON switches, both power supply 1 (PSU1) and power supply 2
(PSU2) are on the right side of the switch.
The S5224F-ON, S5232F-ON, or S5248F-ON PSUs:
5
48 Power supplies