EasyManua.ls Logo

Dell EMC PowerSwitch S4100-ON Series - Optics Installation

Dell EMC PowerSwitch S4100-ON Series
205 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 22. Front rack installation
NOTE
: Do not the use the mounted Ready-Rails as a shelf or a workplace.
3 Tighten the two thumb screws and rack screws.
To remove the chassis from the rack or cabinet, press in the two side-release bars on the chassis at the same time and slide the chassis
forward.
Optics installation
The S4100-ON Series (S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148T-ON, and S4148U-ON) switch has the following optic
congurations:
NOTE
: For the S4148U-ON, for the best optics performance, upgrade the Dell EMC software to 10.4(0.0) or higher.
Table 15. S4100-ON Series optic congurations
Platform Description
S4128F-ON
28 xed SFP+ optical ports
2 xed QSFP28 optical ports
S4148F-ON
48 xed SFP+ optical ports
2 xed QSFP+ optical ports
4 xed QSFP28 optical ports
S4148FE-ON
24 LRM-capable xed unied SFP+ optical ports
24 LRM-capable xed SFP+ optical ports
32 S4100–ON Series installation

Table of Contents

Related product manuals