EasyManua.ls Logo

Dell POWERCONNECT 5524P - Page 48

Dell POWERCONNECT 5524P
728 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
48 Dell PowerConnect 55xx Systems User Guide
Loading Software onto Stack Members
Rebooting the Stack
Managing Configuration Files on the Stack
Adding a Unit to the Stack
The recommended procedure to add a unit to a stack is as follows:
1
Place the powered-off unit in its physical place in the stack, and insert the
stacking link in the unit (but do not connect it to the rest of the stack).
2
Power up the unit, and set the correct Unit ID, as described below.
3
Reboot the unit and connect it to the rest of the stack through the stack
link.
Assigning Unit IDs
Each unit in the stack has a unique ID that defines the unit’s position and
function in the stack, as shown in Figure 5-2.
The unit that is assigned Unit ID 1 is the Master unit, by default. The unit
that is assigned Unit ID 2 is the Master Backup unit.
When you power-up the stack, each unit is assigned a unique Unit ID. This is
displayed on the front panel of the unit, as shown in Figure 5-2.
The Unit ID of each unit can be either automatically assigned or manually
assigned, as described in step 1 to step 4 below.
To assign IDs to the units in the stack, do the following for each unit in the
stack:
1
Connect the unit to the terminal.

Table of Contents

Related product manuals