cfgChassisDefaultPowerCapLowerBound (Read Only)
Description
Displays the default power cap lower bound value.
Legal Values
None
Default
2715 W
cfgChassisDefaultPowerCapUpperBound (Read Only)
Description
Displays the default power cap upper bound value.
Legal Values
None
Default
16685 W
cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
Description
Displays the default power cap upper bound value using British Thermal Unit (BTU).
Legal Values
None
Default
56931 BTU/h
cfgChassisPowerCap (Read or Write)
Description
Indicates the maximum power consumption limit (in watts) for the entire chassis. The command generates an
error if server throttling is necessary to achieve the power goal based on the value for this setting.
Legal Values
2715–16685 watts
Default
16685 watts
cfgChassisPowerCapF (Read or Write)
Description
Indicates the maximum power consumption limit (in watts) for the entire chassis. Use
cfgChassisPowerCapF when power consumption changes regardless of whether server throttling is
required. This command generates an error if the value for this setting is lower than the minimum power
required for the chassis conguration.
Legal Values
271–16685 watts
Default
16685 watts
cfgChassisPowerCapBTU (Read or Write)
Description
Indicates the maximum power consumption limit (in BTU/hr) for the entire chassis. The command generates
an error if server throttling is necessary to achieve the power goal based on the value for this setting.
Legal Values
9264–56931 BTU/hr