server-5 Not Present None None
server-6 Not Present None None
server-7 Not Present None None
server-8 Present LPe1105-M4 None
server-9 Extension(1) None None
server-10 Not Present None None
server-11 Not Present None None
server-12 Not Present None None
server-13 Not Present None None
server-14 Not Present None None
server-15 Not Present None None
server-16 Not Present None None
getexaddr
Description
Displays enabled or disabled status for the entire chassis and fabric ID decoder. If used with the -i option, the
command displays MACs/WWN addresses on a per slot basis.
The decoder values indicate the protocols of the network cards:
0 — Unsupported
1 — ISCSI
2 — FCoE-FIP
3 — iSCSI/FCoE-FIP
To run this subcommand, you must have the CMC Login User privilege.
NOTE: If FlexAddress is not activated on the chassis, the command displays server-assigned
MAC/WWN addresses. If the slot is empty, the command enters blank in the server-assigned
MAC/WWN addresses. If an external console controls the MAC/WWN addresses, the command
displays an externally managed message.
Synopsis
racadm getflexaddr [-i <slotNum>]
Input -i <slotNum>Species the slot information that must be displayed. <slotNum> can be from 1 to 16.
Output None
Example
Display current exaddress settings for all slots and fabrics.
racadm getflexaddr
<Slot#> <Status> <Server Presence>
1 Enabled Present
2 Enabled Present
33