cfgAlertingEnable (Read or Write)
Description
Enables or disables event traps on the CMC.
Legal Values
1 (true)
0 (false)
Default
None
cfgAlertingFilterMask (Read or Write)
Description
Sets the event lter.
Legal Values
Hex values 0x0 — 0x1f
Default
0x178db
cfgAlertingSourceEmailName (Read Only)
Description
Species the email address used to send email notications when an event occurs.
Legal Values
None
Default
None
Examples
racadm getconfig -g cfgAlerting -o cfgAlertingSourceEmailName
racadm config -g cfgAlerting -o cfgAlertingSourceEmailName user@home.com
Object value modified successfully
cfgIPv6LanNetworking
This group is used to congure the IPv6 over LAN networking capabilities.
Use this object with the cong or getcong subcommands.
To use this object property, you must have Chassis Conguration Administrator privilege.
The following sections provide information about the objects in the cfgIPv6LanNetworking group.
cfgIPv6Enable (Read or Write)
Description
Enables or disables CMC IPv6 stack.
Legal Values
1 (TRUE)
0 (FALSE)
Default
0