cfgRacTuning
This group is used to congure various conguration properties, such as valid ports and security port restrictions.
Use this object with the cong or getcong subcommands.
To use this object property, you must have the Chassis Conguration Administrator privilege.
NOTE: You can congure a setting that does not have the hash sign (#) prexed in the output. To modify a congurable
object, use the
—o option.
The following sections provide information about the objects in the cfgRacTuning group.
NOTE: Only the following objects are displayed, if —m option is used:
cfgRacTuneWebserverEnable
cfgRacTuneHttpPort
cfgRacTuneHttpsPort
cfgRacTuneTelnetPort
cfgRacTuneSshPort
cfgRacTuneRemoteRacadmEnable (Read or Write)
Description
Enables or disables the Remote RACADM interface.
Legal Values
1 (TRUE)
0 (FALSE)
Default
1
cfgRacTuneIdracDNSLaunchEnable (Read or Write)
Description
Congure iDRAC or CMC GUI launch using IP or DNS.
Legal Values
1 — Enabled (launch iDRAC or CMC using DNS name)
0 — Disabled (launch iDRAC or CMC using IP address)
Default
0 — Disabled
cfgRacTuneEnhancedLog (Read or Write)
Description
Enables or disables the enhanced chassis log feature.
Legal Values
1 — Enable
0 — Disable
Default 0