NOTE: If a server takes longer duration to turn o gracefully after the chassis power cycle is
initiated, CMC stops functioning indicating that graceful shutdown of the server was
unsuccessful. In this case, you must ungracefully turn o the system or try to gracefully turn o
the system again.
—nongraceshutdown — (Chassis only) Turns o the chassis ungracefully.
—reset — Performs a hard reset of the module.
When <module> = kvm or switch, <action> must be powercycle or reset.
Output
None
Example
Perform a reset of switch-3:
racadm chassisaction -m switch-3 reset
Module power operation successful.
Perform a non graceful shutdown of the chassis:
racadm chassisaction -m chassis nongraceshutdown
chassislog
Description Displays chassis log and management operations.
Synopsis
racadm chassislog <chassislog command type>
Input chassislog command types:
view — View chassis log
To View chassis log
racadm chassislog view
export — Export to local disk and network share
Export chassis log to local disk
racadm -r 192.168.0.32 chassislog export -f filename.log
Export chassis log to network share CIFS
racadm -r 192.168.0.32 chassislog export -f //192.168.0.120/data/
filename.log
Export chassis log to network share NFS
racadm -r 192.168.0.32 chassislog export -f 192.168.0.120/data/
filename.log
clear — Clear chassis log
To clear chassis log
racadm chassislog clear
NOTE: To clear the chassis log, you must have the Clear Logs Administrator privilege.
NOTE: racadm chassislog export -f <filename> is supported only for remote
interface(s).
closessn
Description
Closes a communication session on the device. Use getssninfo to view a list of sessions that can be closed
using this command.