NOTE:
10 GbE KR/3— The value 3 indicates that the fabric is iSCSI/FCoE-FIP.
getfanreqinfo
Description Displays fan speed request for servers and switches in percent (%).
To run this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getfanreqinfo
Input N/A
Output None
Example
racadm getfanreqinfo
[Ambient Temperature Fan Request %]
38
[Server Module Fan Request Table]
<Slot#> <Server Name> <Blade Type> <Power State> <Presence> <Fan
Request%>
1 SLOT-01 N/A N/A Not Present N/A
2 WIN-JGKC47ACGKG PowerEdge M630 ON Present 38
3 WIN-N24BRAT3L1J PowerEdge M630 ON Present 38
4 SLOT-04 PowerEdge M630 ON Present 17
5a nodea.NOBLEEST.CO
M
PowerEdgeM420 ON Present 43
5b SLOT-05b PowerEdgeM420 ON Present 43
5c WIN-UMJ7OP4BIN3 PowerEdgeM420 ON Present 100
5d SLOT-05d PowerEdge M420 ON Present 43
6 SLOT-6 PowerEdge M820 ON Present 27
7 SLOT-7 PS-M4110 N/A Present 58
8 SLOT-8 N/A Extension(7) N/A N/A
9 SLOT-9 N/A Present 0
10 SLOT-10 N/A Present 0
11 SLOT-11 ON Present 38
12 SLOT-12 N/A Extension(4) N/A N/A
13 SLOT-13 N/A Extension(5) N/A N/A
14 SLOT-14 N/A Extension(6) N/A N/A