EasyManua.ls Logo

Dell PowerEdge M1000e - Getarraycfg; Getassettag

Dell PowerEdge M1000e
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Severity = Critical
Message = The power input for power supply 1 is lost.
Module ID = ps-3
Severity = Critical
Message = The power input for power supply 3 is lost.
Module ID = cmc-1
Severity = NonCritical
Message = A firmware or software incompatibilty detected between system
BIOS in slot 4 and CMC.
Display specic module log:
racadm getactiveerrors -m server-1
getarraycfg
Description
To display the storage array properties and conguration status, run this command.
Synopsis
getarraycfg -m <module> [-s]
Input
-m — The valid value for —m <module> is server–<n>, where n = 1 to 7 and 9 to 15.
-s — Query for current storage conguration process status.
Output Array congured properties for:
Member Name
Member IP
Group Name
Group IP
Fabric Selection
<module> conguration completed successfully.
Example
Get the congured storage array properties from server–3.
racadm getarraycfg -m server-3
Query for current storage conguration process status on server–3.
racadm getarraycfg -m server-3 -s
getassettag
Description
Displays the asset tag for the chassis.
To run this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getassettag [-m <module>]
Input -m <module>Species the module whose asset tag you want to view.
Legal value: chassis
Example
Display asset tag for chassis
racadm getassettag -m chassis
racadm getassettag
chassis 78373839–33