racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the server in slot 1.
NOTE: The setled command generates an error when run on the extension slot of a multi-slot
server.
setniccfg
Description Sets the iDRAC or CMC IP address for static and DHCP modes.
To run this subcommand, you must have the Congure Chassis Administrator privilege.
NOTE: The command helps to modify network conguration properties.
NOTE: The terms NIC and Ethernet management port may be used interchangeably.
Synopsis
racadm setniccfg [-m <module>] -d [-6]
racadm setniccfg [-m <module>] -s <ipAddress> <netmask> <gateway>
racadm setniccfg [-m <module>] -s -6 <ipv6Address> <prefixlen> <gateway>
racadm setniccfg [-m <module>] -v [<vlan_id> <vlan_priority>]
racadm setniccfg [-m chassis] -o
racadm setniccfg –p [-6]
racadm setniccfg [-m <module>] -k [<speed> <duplex>]
racadm setniccfg [-i <slot>] -v [<vlan_id> <vlan_priority>]
Input
-d — Enables DHCP for the NIC. It is enabled by default.
-d6 — Enables AutoCong for the NIC (default is disabled).
-s — Enables static IP settings. The IPv4 address, netmask, and gateway must be specied. Otherwise,
the existing static settings are used. <ipaddress>, <netmask>, and <gateway> must be typed as
dot-separated strings.
racadm setniccfg -s 192.168.0 255.255.255.0 192.168.0
-s6 — Enables static IPv6 settings. The IPv6 address, Prex Length, and the IPv6 Gateway can be
specied.
-o — Enable or disable NIC.
-m<module> — Must be one of the following values:
chassis — Default state if -m is not specied
server–<n>: where n=1–16
server–<nx>: where n=1–8; x=a–d (lower case)
switch–<n>: where n=1–6
-v — VLAN settings has following legal values: no arguments imply remove VLAN tag, not compatible with
server–nx (for example "server–4b") notation <vlan_id>=between 1 and 4000, 4021 and 4094, inclusive
<vlan_priority>=between 0 and 7, inclusive.
-p — Disables IPv4(default) or IPv6 protocol.
-k — Option has following legal values: no arguments imply autonegotiate <speed>=10, 100 <duplex>
=half, full.
NOTE:
-o, -k, -p: These options can be specied for chassis only
-6: Sets static IPv6 addresses (with -soption). Enables autocong for IPv6 (with-d option) disables
IPv6 (with
-p option) can be specied for chassis or servers.
-v: When performing on a switch, release and renew any DHCP lease on that port for changes to
take eect.