Displays the Lifecycle Controller component versions for servers 1 and 3.
racadm getversion -l -m server-1 -m server-3
racadm getversion -m server-1
<server> <iDRAC version> <Blade Type> <Gen> <Updatable>
server-1 1.40.40 (Build
08)
PowerEdge M520 iDRAC Y
server-2 3.50 (Build 2) PowerEdgeM610x iDRAC6 Y
server-4 3.50 (Build 4) PowerEdgeM710HD iDRAC6
racadm getversion -c
<
Server> <CPLD Version> <Blade Type>
server-1 1.0.5 PowerEdgeM520
server-2 1.0.3 PowerEdgeM610x
server-4 1.0.0 PowerEdgeM710HD
server-5 1.0.3 PowerEdgeM710
server-7 1.0.6 PowerEdgeM620
server-9 1.0.5 PowerEdgeM520
racadm getversion -l -m server-1
<
Server> <Component> <Version> <Install Date>
server-1 BIOS 1.6.0 2013-01-09
iDRAC1.40.40 1.40.40 2013-01-31
USC 1.1.5.154 2013-04-16
Diagnostics 4225A2 2012-12-21
OS Drivers 7.2.0.7 2012-12-21
BIOS 1.5.2 Rollback
BP12G+ 0:1 0.16 Reinstall
iDRAC Rollback
System CPLD 1.0.5 1999-12-31
NIC-Broadcom Gigabit
Ethernet BCM5720 - BC:
30:5B:97:06:C4
7.6.6 Rollback