Racdump includes the following subsystems and aggregates the following RACADM commands:
General System/RAC information — getsysinfo
Session information — getssinfo
Sensor information — getsensorinfo
Switches information (IO Module) — getioinfo
Mezzanine card information (Daughter card) — getdcinfo
All modules information — getmodinfo
Power budget information — getpbinfo
KVM information — getkvminfo
NIC information (CMC module) — getniccfg
Redundancy information — getredundancymode
Trace log information — gettracelog
RAC event log — getraclog
System event log — getsel
Synopsis
racadm racdump
Input N/A
Output
The following information is displayed when this subcommand is processed:
General system or RAC information
Coredump
Session information
Process information
Firmware build information
Example
racadm racdump
===============================================================================
General System/RAC Information
===============================================================================
CMC Information:
CMC Date/Time = Wed, 28 Nov 2007 11:55:49 PM
Active CMC Version = X08
Standby CMC Version = N/A
Last Firmware Update = Wed Nov 21 21:37:56 2007
Hardware Version = 2
Current IP Address = 192.168.0.1
Current IP Gateway = 192.168.0.1
Current IP Netmask = 192.168.0.1
DHCP Enabled = 1
MAC Address = 00:55:AB:39:10:0F
Current DNS Server 1 = 0.0.0.0
Current DNS Server 2 = 0.0.0.0
DNS Servers from DHCP = 0
Register DNS CMC Name = 0
DNS CMC Name = cmc-servicetag
Current DNS Domain =
Chassis Information:
System Model = PowerEdgeM1000eControlPanel
System AssetTag = 00000
Service Tag =
Chassis Name = Dell Rack System
Chassis Location = [UNDEFINED]
60