NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 151. Installing the right control panel
Next steps
1. Install the side wall bracket.
2. Install the cooling fan cage assembly.
3. Install the drive backplane cover.
4. Install the air shroud.
5. Follow the procedure listed in After working inside your system.
Removing the left control panel
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the drive backplane cover.
4. If installed, remove the air shroud.
5. Remove the cooling fan cage assembly.
6. Remove the side wall bracket.
Steps
1. Using the Phillips #1 screwdriver, remove the screws that secures the left control panel and the cable cover to the system.
2. Remove the cable cover away the system.
3. Disconnect the control panel cable from the connector on the system board.
4. Holding the cable, slide the left control panel out of the system.
NOTE: Observe the routing of the cable as you remove the right control panel from the system.
178 Installing and removing system components