Chapter 4 Parameters
VFD-EL-W 
4-97 
 
Optional Accessories for Multi-pumps under Alternative Operation 
When you use the multi-pump operation, pay attention to the following wirings. 
 
1.  Use a RJ45 cable (8 pin, Internet cable) without an adapter. Simply connect the master/slave communication 
port. If there are more than two pumps, use RMKE-HUB01 to connect RJ45. 
 
 
RJ45 Female Connector 
RMKE-HUB01 
RS-485 One-wire to Two-wire 
 
 
2.  Use a RJ11 (6 pin) cable with an adapter to connect the master/slave communication port.  
VFD-CMD04 
RS-485 RJ11 
Four-port communication breakout box 
 
 Case: 
For alternative operation of multi-pump (Pr.10.35=1 Fixed Time Circulation) 
  Enables four pumps to operate alternatively by time to extend their life span. 
  Keeps the water pressure at 3 kg in a water system with constant pressure. 
Refer to the diagram below: