Chapter 1 Introduction 
 VFD-EL-W 
   
   
1-9
 
1.  Due to a small protruding part of the heat-sink at the bottom of the Frame A1/ A2, we calculate the distance C 
for the side-by-side horizontal installation according to the main part of the motor drive only. 
2.  Frame A1 and A2 does not support zero-stack installation, whereas Frame B supports zero-stack installation.  
3.  Running the drive continuously with full load by the ambient temperature listed in the “Max. ( Derating is not 
requiered)” column reduces the drive’s life span.  
4.  After installing a cooling fan to VFD007EL21W(-1), the operating temperature of this model is as shown in the 
table above. When VFD007EL21W(-1) doesn’t have cooling fan, its operating temperature should be 10 ºC 
lower than the temperature shown above (See Cooling Fan Installation in Appendix B.4).