Chapter 4 Parameters
VFD-EL-W 
4-37 
 
 
Therefore, the motor’s operation distance after executing the stop command = number of revolutions x 
circumference = 175 x 2 πr. It also menas that the swivel table goes back to the top after 175 revolutions.  
 
Example 2 
Assume that the motor swivel table rotates at 1.5 Hz, and Pr.01.22 = 10 Hz [Simple Positioning Stop Frequency 2], 
and Pr.01.30 = 10 sec. [Delay Time of Simple Positioning Stop 2], then the deceleration time from 60 Hz to 0 Hz is 
40 seconds.  
 
The delay time at stop for 1.5 Hz is 1.5 second; the deceleration time from 1.5 Hz to 0 Hz is 1 second. 
 
After executing the stop command, Simple Positioning Stop activates, its rotation speed is  
n = 120 x 1.5 / 4 (revolution / minute) = 1.5 / 2 (revolution / second) 
The number of revolution of the swivel table = (1.5 / 2 x (1.5 + 2.5)) / 2 = 1.5 (revolutions) 
 
Therefore, the motor’s operation distance after executing the stop command = number of revolutions x 
circumference = 1.5 x 2 πr. It also means the swivel table stops after running 1.5 revolutions.