Network commissioning and diagnostics Binding
XBee/XBee-PR S2C ZigBe RF Module
114
process is over, both devices will have entries in their binding tables which support indirect addressing
of messages between their bound endpoints.
R1->C End_Device_Bind_req
R2->C End_Device_Bind_req
R1, R2 send End_Device_Bind_req within 60 s of each other to C
C matches the requests.
C tests one to see if binding is already in place:
R2<-C Unbind_req
R2->C Unbind-rsp (status code - NO_ENTRY)
C proceeds to create binding table entries on the two devices.
R1<-C Bind_req
R1->C Bind_rsp
R2<-C Bind_req
R2->C Bind_rsp
C sends responses to the original End_Device_Bind_req messages.
R1-<C End_Device_Bind_rsp
R2-<C End_Device_Bind_rsp
End Device binding sequence (binding)
This message has a toggle action. If the same two devices were to subsequently send End_Device_
Bind_req messages to the Coordinator, the Coordinator would detect they were already bound, and
then send Unbind_req messages to remove the binding.
An installer can use this to remove a binding which was made incorrectly, say from a switch to the
wrong lamp, by repeating the commissioning button sequence used beforehand.
R1->C End_Device_Bind_req
R2->C End_Device_Bind_req
R1, R2 send End_Device_Bind_req within 60 s of each other to C
C matches the requests.
C tests one to see if binding is already in place:
R2<-C Unbind_req
R2->C Unbind-rsp (status code - SUCCESS)
C proceeds to remove binding table entries from the two devices.
R1<-C Unbind_req
R1->C Unbind_rsp
R2<-C Unbind_req
R2->C Unbind_rsp
C sends responses to the original End_Device_Bind_req messages.
R1-<C End_Device_Bind_rsp
R2-<C End_Device_Bind_rsp
End Device binding sequence (removal)
This example shows a correctly formatted End_Device_Bind_req (ZDO cluster 0x0020) using a Digi
0x11 Explicit API Frame:
The frame as a bytelist:

Table of Contents

Other manuals for Digi XBee

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBee and is the answer not in the manual?

Digi XBee Specifications

General IconGeneral
Operating Frequency2.4 GHz
RF Data Rate250 kbps
ModelXBee S2C
CategoryControl Unit
Operating Voltage2.1 to 3.6V DC
Operating Temperature-40 to +85 °C
InterfaceUART