EasyManuals Logo

Digi XBee User Manual

Digi XBee
307 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #216 background imageLoading...
Page #216 background image
API Operation Send Public Profile Commands with the API
XBee/XBee-PR S2C ZigBe RF Module
216
Frame Fields Offset
Description
Device class 30
This bit encoded field represents the Device Class
associated with the Load Control Event. A bit value of
0x0014 enables smart appliances and water heaters.
Note The 2-byte bit field value is sent in little endian
byte order.
31
Utility
enrollment
group
32 Used to identify sub-groups of devices in the device-
class. 0x00 addresses all groups.
Start time 33
34
35
36
Duration in
minutes
37 This 2-byte value must be sent in little endian byte
order.
38
Criticality
level
39 Indicates the criticality level of the event. In this
example, the level is “voluntary”.
Cooling
temperature
40
Requested offset to apply to the normal cooling set
point.
A value of 0xFF indicates the temperature offset
value is not used.
Heating
temperature
offset
41
Requested offset to apply to the normal heating set
point.
A value of 0xFF indicates the temperature offset
value is not used.
Cooling
temperature
set point
42
Requested cooling set point in 0.01 degrees Celsius.
A value of 0x8000 means the set point field is not
used in this event.
Note The 0x80000 is sent in little endian byte order.
43

Table of Contents

Other manuals for Digi XBee

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBee and is the answer not in the manual?

Digi XBee Specifications

General IconGeneral
Operating Frequency2.4 GHz
RF Data Rate250 kbps
ModelXBee S2C
CategoryControl Unit
Operating Voltage2.1 to 3.6V DC
Operating Temperature-40 to +85 °C
InterfaceUART
Dimensions24.38 x 27.61 x 9.14 mm

Related product manuals