ZigBee networks ZigBee router operation
XBee/XBee-PR S2C ZigBe RF Module
67
Leave a network
The following mechanisms cause the coordinator to leave its current PAN and start a new network
based on its network formation parameter values.
n Change the ID command such that the current 64-bit PAN ID is invalid.
n Change the SC command such that the current channel (CH) is not included in the channel
mask.
n Change the ZS or any of the security command values (excluding NK).
n Issue the NR0 command to cause the coordinator to leave.
n Issue the NR1 command to send a broadcast transmission, causing all devices in the network
to leave and migrate to a different channel.
n Press the commissioning button 4 times or issue the CB command with a parameter of 4.
n Issue a network leave command.