Digital Dream Standalone Motion Controller DDCS V3.1 DDCS V3.1 Users Manual Page -71
A) #446:0: Starts the machine;
1: Find the middle,need to work with MPG,the fuction is same as F3 of the Keyboard;
2: Runs the code contained in the file extkey1.nc ;
3: Shift between 4 kinds JOG distances(#2020,#2021,#2022,#2023).
B) #447:0: Pauses the machine ;
1: Zero all axes in current coordinate system ;
2: Runs the code contained in the file extkey2.nc ;
3: Start/Pause Key.Note: The function only can work when processing the G-code file .
14) Backlash Parameters(Totally 8 Items)
15 ) Tool Offset (Totally 32 Items)
#437 Enable of X axis backlash
Enable of Y axis backlash
Enable of Z axis backlash
Enable of A axis backlash
0 BOOL 1/0
0 BOOL 1/0
0 BOOL 1/0
0 BOOL 1/0
#438
#439
#440
#441 X axis backlash distance
Y axis backlash distance
Z axis backlash distance
A axis backlash distance
0 mm 0~0.999
0~0.999
0~0.999
0~9.999
0 mm
0 mm
0 deg
#442
#443
#444
Para.
Mark
Parameter definition
Default
value
Param
Scope
Param
Unit
Notes
Set the backlash return as you
need for each axis.
Tip: experiment with the settings
and check the results
0:Disable,1:Enable
-999.999 ~ 999.999
This H group is for
Tool Length Compensation
#268 H01 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#267 H00 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#269 H02 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#270 H03 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#271 H04 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#272 H05 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#273 H06 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#274 H07 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#275 H08 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#276 H09 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#277 H10 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#278 H11 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#279 H12 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#280 H13 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#281 H14 Tool Offset 0.000 BOOL
-999.999 ~ 999.999#282 H15 Tool Offset 0.000 BOOL
Para.
Mark
Parameter definition
Default
value
Param
Scope
Param
Unit
Notes
13 ) External Button Parameters(Totaly 7 items)
0=Low,1=High
0=Low,1=High
0=Low,1=High
0=Disable 1; 1=Enable
0=Disable 1; 1=Enable
Para.
Mark
Parameter definition
Default
value
Param
Scope
Notes
1/0
1/0
1/0
1/0
1/0
#423 Enable signal of extended ESTOP 1
#424 Electric level of ext-ESTOP signal 0
#425 Enable extended START&PAUSE 1
0~3
0
0~3
0
0
0
#426
#427 Electric level of Ext-key2
Electric level of Ext-key1
#446
#447 Define the Function of Ext-key2
Define the Function of Ext-key1 0: START; 1: Find Middle; 2: "extkey1.nc" ; 3: JOG-D
0: PAUSE; 1: ZERO; 2: "extkey2.nc" ; 3: S/P ctrl