Important Information
 
   
Symbols used in the User Manual   
 
LASER WARNING: this symbol indicates that there is a potential hazard of eye exposure to laser radiation unless the 
instructions are closely followed. 
 
ELECTRICAL WARNING: this symbol indicates that there is a danger of electrical shock unless the instructions are 
closely followed. 
 
WARNING: this symbol indicates that there is a danger of physical injury to yourself and/or damage to the equipment 
unless the instructions are closely followed. 
 
 NOTE: this symbol indicates that there is some important information that you should read. 
 
 
 
Specifications are subject to change without notice. 
 
Electrical and physical specifications  
Mains Voltage    200-240 VAC 
50-60 Hz (single phase) 
Operating Temperature  0°C to 35°C 
Storage Temperature  -20°C to 60°C 
Operating Humidity    20% to 90% non-condensing 
Weight      63 kg (138.9 lb) without lens 
Power Consumption  1608 W 
Thermal Dissipation   5027 BTU/hr 
 
Non-accessible laser parameters  
 
Wavelength   
435 - 462 nm 
Laser Power for classification  < 330 mW 
Total internal power   < 35 W 
Apparent Source Size  < 10 mm at aperture 
Divergence    ≤ ± 7.3 - 28°, lens dependent 
Mode of operation    CW 
Modulation, due to frame rate  23 - 192 Hz 
 
 
   