22
© 2015 Directed. All rights reserved.
7. Accessory State During Wait-To-Start Off/On (Orange wire on 10-pin harness):
This feature will allow the selection of the accessory output to be ON or OFF during WTS.
8. Status Output (Dark Blue wire on 24-pin harness):
1. Status Normal: The output will activate before the ignition outputs turn on, and de-activate after they
turn off during remote start.
2. Latch Rear Defogger: The output activates 10 seconds after start if the temperature at the main unit is
below 55F°. It turns off after 10 minutes or upon remote start off.
3. Pulse Rear Defogger: The output activates (for 800 ms) 10 seconds after start if the temperature at the
main unit is below 55F°.
9. Anti-grind Output (Orange wire on 5-pin harness):
On/Off: With the anti-grind On (default) the GWA (Ground-When-Armed) output will be active during
remote start operation. If accessories such as a voice module or window module are added to the unit,
it may be necessary to program this feature off.
10. Diesel Start Delay (Gray/Black wire on 24-pin harness):
1. WTS (Wait-to-Start) Input: (-) Input on the Gray/Black WTS wire will delay the starter output until the
ground ceases.
2. Timed 15/30/45 seconds: Delays the starter output per the selected option, the WTS wire does not
function.
11.
Timer Mode Runtime:
12, 3, 6, 9 Minutes: Selects the time in minutes that the system will operate the engine until the system
"times out". Using the Bitwriter, the run time can be programmed for any duration from 1-16 minutes.
12. Timer/Temp Mode Start Type:
1. Timed Start Mode: The system will start every three hours (a maximum of six times) until canceled by the
brake, hood, turning on the ignition, or parking brake/emergency brake shut-down wires.
2. Temperature Start Mode will not start the vehicle unless the interior temperature of the vehicle is less
than zero degrees fahrenheit. The Temperature Start Mode will exit after 18 hours.
13. Short Engine Runtime/Turbo Mode:
1/3/5/10 Minutes: When Turbo Mode is activated, the engine will run for the duration set per the
selected option.