EasyManua.ls Logo

Directed 5305 - Bitwriter Options and Reset Procedures; Bitwriter Only Options

Directed 5305
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Bitwriter - Only Options
If programming with the Bitwriter, the Learn Routine can be locked or unlocked. If the Learn Routine
has previously been locked, it must be unlocked with Bitwriter - this cannot be done manually with the
Control Center button.
The Bitwriter gives you access to a wider range of system options. These features and the adjustments
that may be programmed are described in the table below.
Menu
Item
Feature Default Options
1 Siren Duration (in seconds)
30 sec.
1-180 sec.
2 AUX 4 Timed Output (in seconds)*
30 sec.
1-90 sec.
3 AUX 5 Timed Output (in seconds)*
30 sec.
1-90 sec.
4 AUX 6 Timed Output (in seconds)*
30 sec.
1-90 sec.
5 Engine Runtime (in minutes)
12 min.
1-60 min.
6 Diesel Start Delay (in seconds)
15 sec.
1-90 sec.
7 Timer Mode Runtime (in minutes)
12 min.
1-16 min.
8 Virtual Tach Fine Tune (in milliseconds)
Not initialized
0-1000 in 50 ms increments
9 Transmitter Programming
Unlocked
Locked
10 Feature Programming
Unlocked
Locked
* On the Bitwriter AUX 4 is labeled as “AUX 2”, AUX 5 as “AUX 3”, and AUX 6 as “AUX 4”.
Note: The “Zap” feature on the Bitwriter does not reset the Virtual Tach or Security Features Enabled/Disabled
settings.
Bitwriter Feature Descriptions
1. Siren Duration:
Sets the siren output for full trigger activations from 1-180 seconds.
2. AUX 4 Timed Output:
Sets the output duration in 1 second intervals up to 90 seconds.
3. AUX 5 Timed Output:
Sets the output duration in 1 second intervals up to 90 seconds.
4. AUX 6 Timed Output:
Sets the output duration in 1 second intervals up to 90 seconds.
5. Engine Runtime:
Sets engine runtime during normal remote start operations from 1-60 minutes.
6. Diesel Start Delay:
Sets the WTS delay before engine crank in 1 second intervals from 1- 90 seconds for diesel engine vehicles.
7. Timer Mode Runtime:
Sets the duration of runtime when the engine is started by the Timer Mode from 1-16 minutes.
8. Virtual Tach Fine Tune:
Adds or subtracts starter crank time in Virtual Tach mode in order to overcome engine types that short crank
or over-crank on the first start attempt.
9. Transmitter Programming:
Locks and unlocks the user’s ability to enter the Remote Control Pairing/Reset menu and manually change any
functions using the Control Center button.
10. Feature Programming:
Locks and unlocks the user’s ability to enter the Feature Menus and manually change the main unit program-
ming using the Control Center.