25
© 2015 Directed. All rights reserved.
Security Features Disable/Enable
The system has the ability to function as a security/remote start system or as a keyless/remote start system by
disabling or enabling the security features/functions. The default setting is Enabled.
To program the feature:
1. Open a door.
2. Turn the ignition on, then off.
3. Press and hold the Control Center button until the Control Center LED flashes three times and the siren (if
connected) chirps three times (the system will enter Feature Menus 1 & 2 and continue to menu 3).
4. Release the Control Center button.
Note: If the Control Center button is released and then pressed again, the system will enter the Program-
ming System Feature Menus.
5. Within 15 seconds, simultaneously press the
A U X
and
A U X
buttons of a programmed remote control.
6. The siren (if connected) will chirp and the parking lights will flash as listed below.
1. Flash/chirp: Security features DISABLED
2. Flashes/chirps: Security features ENABLED
Security features disabled will disable all security operations of the system, including but not limited to the
following:
Multi Level Arming
Sensor Warn-Away
Full Trigger Operation
AWD (Armed While Driving)
AED (Automatic Engine Disable)
Note: Disabled features with programmable options can still be programmed manually or with the Bitwriter
but will not operate until the until the Security Features have been enabled.
The Security Features Disable/Enable routine exits if the following occurs:
The open door is closed.
The ignition is turned On.
There is no activity for 15 seconds.
The Control Center button is pressed too many times.
Long Term Event History
The system stores the last two full triggers in memory. These are not erasable. Each time the unit sees a full trig-
ger, the older of the two triggers in memory is replaced by the new trigger. To access long term event history:
1. With the ignition Off, press and hold the Control Center button.
2. Turn the ignition On.
3. Release the Control Center button.
4. Within five seconds, press and release the Control Center button. The status LED flashes in groups indicat-
ing the last two zones that triggered the unit for one minute or until the ignition is turned off. Refer to Table
of Zones for more information.
Note: The Warn Away triggers are not stored to memory and is not reported.