Service - 212 JT40/JT40 All Terrain Operators Manual
Startup/10 Hour
Check Hydraulic Fluid Level
Check hydraulic fluid level before startup and every
10 hours of operation. Maintain fluid level at halfway
point on sight glass (2), when unit is on level
ground, engine is off, and fluid is cool. Add THF at
hydraulic fluid fill (1) as needed.
Check Fluid Pump Oil Level
Check fluid pump oil level at sight glass (1) before
startup and every 10 hours of operation. Add MPL
at fill (2) as needed.
Check Pipe Auto Lubricator Level
Check pipe auto lubricator TJC level before startup
and every 10 hours of operation. Change pail as
needed. See “Change Auto Lubricator Pail” on
page 230 for procedure.
IMPORTANT: If hydraulic system must be
opened for repair, install new filter (p/n 153-791)
for first 50 hours of operation. If this filter
becomes plugged in fewer than 20 hours,
replace with new filter. After 50 hours of normal
operation, replace with new filter (p/n 153-792).
NOTICE: Ditch Witch
®
tool joint compound is
specially formulated to work with Ditch Witch pipe
lubrication system. Use of other tool joint
compounds will clog system. See
“Recommended Lubricants/Service Key” on
page 202 for more information.
1
2
j59om024w.eps
j59om090w.eps
1
2
j59om026w.eps

Table of Contents