JT40/JT40 All Terrain Operator’s Manual Service - 227
2000 Hour
Change Fluid Pump Oil
Change fluid pump oil every 2000 hours.
To change:
1. Drain at plug (3). Ensure that magnetic drain
plug is cleaned of debris before reinstalling.
2. Add 2.8 qt (2.6 L) MPL at fill plug (2). Maintain
fluid level at sight glass (1).
Replace Crankcase Breather Filter
(HRC Only)
Replace crankcase breather filter every 2000 hours.
To replace:
1. Disconnect crankcase ventilation hose (1).
2. Turn breather housing cover (2)
counterclockwise.
3. Remove filter element (3).
4. Install the new filter element either end up in the
crankcase ventilation breather housing.
5. Install breather housing cover and turn
clockwise.
6. Install crankcase ventilation hose.