23
IP2246EN
EN
11.3 Second level menu - BC (Basic Configurations)
Display Description Selections available
AC - Enabling of automatic closure
ON - Enabled
1-2 - Dependent on input 30-2
SS - Selection of automation status at start
OP - Open
CL - Closed
Indicates how the control panel considers the automation at the time
of switch-on, or after a POWER RESET command.
SO - Enabling of reversal safety contact functioning
ON - Enabled
OF - Disabled
When enabled (ON) with the automation idle, if the contact 1-8 is open, all ope-
rations are prevented.
When disabled (OF) with the automation idle, if the contact 1-8 is open, opening
operations are permitted.
NI - Enabling of NIO electronic anti-freeze system
ON - Enabled
OF - Disabled
When enabled (ON), it maintains the efficiency of the motor even at low ambient
temperatures.
NOTE: for correct operation, the control panel must be exposed to the same am-
bient temperature as the motors.
The intervention temperature for NIO can be set by selecting
.
11.3.1 Additional BC level parameters that can be configured (availa-
ble with
enabled)
Display Description Selections available
C5 - Operation of command associated with contact 30-5
1-5 - Step-by-step
1-3 - Opening
35 - Operation of command associated with contact 30-3
1-5 - Step-by-step
1-3 - Opening
RM - Radio receiver operation
1-5 - Step-by-step
1-3 - Opening
AM - Operation of AUX1 plug-in control board
1-5 - Step-by-step
1-3 - Opening
AN - Operation of AUX2 plug-in control board
1-5 - Step-by-step
1-3 - Opening
MP - Start-up at maximum power
ON - During start-up it increases the thrust on obstacles to maximum
OFF - During start-up, the thrust on obstacles is at the level adjusted by
-
PP - Setting step-by-step sequence from command 30-5
ON - Opening-Stop-Closing-Stop-Opening
OF - Opening-Stop-Closing-Opening
S5 - Duration of STOP in step-by-step sequence from command 30-5
ON - Permanent
OF - Temporary
BC - Basic configurations
BC - Basic configurations