Display Description Selections
available
WC - Setting of pre-flashing time on closing [s]
Adjustment of the lead time for the switch-on of the flashing light, in
relation to the start of the closing operation from a voluntary command.
00 - Minimum
05 - Maximum
00’’
TS - Setting of renewal of automatic closing time after safety device
release [%]
00 - Minimum
99 - Maximum
99
VR - Setting of learning speed [V]
See paragraph 11.2.1
12. Diagnostics
The Ditec LCU40H control panel is equipped with an internal system that allows the
installer to check whether any alarms have been triggered, how many times, and the
log of the last twenty alarms.
With the third level menus enabled (
), go to to see the alarm log (the
last 20 alarms recorded). The display shows the alarm number and code, alternated.
The highest number corresponds to the most recent alarm and the lowest number
corresponds to the oldest alarm.
Example:
_ _ _ _ ....
Use and to scroll through the alarm log.
With the third level menus enabled (
), go to to see all the alarms
recorded by the control panel. The display alternately shows the alarm code and the
number of times it was triggered.
Example:
_ _ _ _ ....
Use the and keys to scroll through the entire list of alarm counters.
12.1 Data Logging integrated in the board
12.1.1 Alarm counter
12.1.2 Alarm log
AP - Advanced parameters