36
IP2246EN
EN
Display Description Selections available
LU - Setting the courtesy light switch-on time (s)
To enable this parameter, set at least one of the selections
or
as a courtesy light.
It is set with different intervals of sensitivity.
NO - Disabled
- from 01” to 59” with intervals of 1 second
- from 1’ to 2’ with intervals of 10 seconds
- from 2’ to 3’ with intervals of 1 minute
ON - Permanently enabled (switched off via remote control)
NOTE: the courtesy light switches on at the start of each operation.
LG - Switch-on time for independently commanded courtesy light [s]
To enable this parameter, set at least one of the selections
or
as a courtesy light.
It is set with different intervals of sensitivity.
NO - Disabled
- from 01” to 59” with intervals of 1 second
- from 1’ to 2’ with intervals of 10 seconds
- from 2’ to 3’ with intervals of 1 minute
ON - Switched on and off with remote control
NOTE: the switching on of the light does not depend on the start of
an operation, but can be commanded separately using the special
remote control key.
PT - Fixed partial opening
ON - Enabled
OF - Disabled
If ON, a partial opening command given on the partial opening position
is ignored.
With contact 30-20 closed (for example with the timer or manual se-
lector), the gate will partially open. If it is then fully opened (command
30-3) and reclosed (even with automatic closing), it will stop at the
partial opening position.
DE - Disengagement duration if an edge is triggered [s]
Regulates the duration of the disengagement when an edge (active or
passive) is triggered during opening or closure.
In the case of gates with two wings, it acts on both wings.
00 - Deactivated
1.0
DO - Duration of disengagement on stop during opening [s/100]
Regulates the duration of the disengagement on the mechanical
opening stop.
00 - Disabled
99 - Maximum
NOTE: not active if
DC - Duration of disengagement on stop during closure [s/100]
Regulates the duration of the disengagement on the mechanical
opening stop.
00 - Disabled
99 - Maximum
NOTE: not active if
11.9.1 Additional AP level parameters that can be configured (available
with
enabled)
AP - Advanced parameters