1592022750 Quick reference guide IC 200CX Rel. 1.1 25/05/2009
ES 10
Thursday energy saving activated
Automatic unit on-off
0 - 0 7 - 7
ES 11
Friday energy saving activated
Automatic unit on-off
0 - 0 7 - 7
ES 12
Saturday energy saving activated
Automatic unit on-off
0 - 0 7 - 7
ES 13
Sunday energy saving activated
Automatic unit on-off
0 - 0 7 - 7
ES 14
Offset for Energy Saving function in chiller mode -30.0
-54
30.0
54
°C
°F
Dec
int
ES 15
Differential for Energy Saving function in chiller 0.1
1
25.0
45
°C
°F
Dec
int
ES 16
Offeset for Energy Saving function in heat pump -30.0
-54
30.0
54
°C
°F
Dec
int
ES 17
Differential for Energy Saving in heat pump 0.1
1
25.0
45
°C
°F
Dec
int
ES 18
Maximum working time of the unit when switched on from keyboard
(and the unit is OFF by Energy saving)
0= Not enabled
0 250 Min 10 Min
Pr1
Password 0 999
Pr2
Password 0 999
Pr3
Password 0 999
Compressors
Param
eters
Description min max udm Risolu
zione
CO 1
Minimum compressor ON time after the start-up 0 250 10 sec
10 sec
CO 2
Minimum compressor OFF time after the switching off 0 250 10 sec
10 sec
CO 3
ON delay time between two compressors or compressor and valve.
1 250 Sec
CO 4
OFF delay time between two compressors or compressor and valve 0 250 Sec
CO 5
Delay time to activate the thermoregulation starting from the power on 0 250 10 Sec
10 sec
Partialization (Capacity Control)
CO 6
Functioning (see Capacity Control)
0= On/off steps
1= Continuous insertion of the steps and direct action
2= Continuous insertion of the steps and reverse action
3= Continuous insertion of the steps
0 3
CO 7
Start-up with minimum compressor power / automatic start-unloading
valve
0 = Only at the compressor start-up (Minimum power automatic start-
unloading valve off)
1= At the compressor start-up and during the termoregulation
(Minimum power / automatic start-unloading valve off)
2 = Only at the screw compressor start-up (Minimum power automatic
start-unloading valve off)
3= At the compressor start-up and during the termoregulation
(Minimum power / Unloading valve ON with compressor off)
0 3
CO 8
ON time of the intermittent solenoid valve for screw compressor
0= the function is not enabled
0 250 Sec
CO 9
OFF time of the inetrmittent solenoid valve for screw compressor 0 250 Sec
Compressor start-up
CO 10
Compressor start-up selection
0= Direct
1= Part - winding
0 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the dixell IC200CX Series and is the answer not in the manual?

dixell IC200CX Series Specifications

General IconGeneral
Branddixell
ModelIC200CX Series
CategoryTemperature Controller
LanguageEnglish

Related product manuals