EasyManua.ls Logo

Dormakaba ED900 - Appendix B - Troubleshooting; Information and Error Codes

Dormakaba ED900
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
47
ED900 09-2021DL4617-001
dormakaba ED900 Setup and Troubleshooting Instructions Appendix B
B. Information and error codes
Appendix B - Troubleshooting
1 4 button keypad
2 2 digit display
Fig. B.1.1 User interface
3 Power switch
4 Red LED
5 Yellow LED
6 Green LED
Fig. B.1.2 Operator LEDs
Fig. B.1.3 Mode switch:
B.. Overview
Operator monitors internal circuits and external safety
circuits managed by the operator.
B.. Error and information messages.
. With operator in use, certain conditions may develop
resulting in error or information messages.
. Operator attempts to identify the cause and respond
accordingly.
. Response depends on the severity of the error:
Information message (ln)
Error message (E)
Deactivating the operator's automatic function;
operator will switch to emergency mode. Users can
then access door manually.
B.. User information display.
User interface display, or or dormakaba handheld
displays:
Information ln codes
Error message E codes
B.. Viewing error messages.
To access and view error messages, briefly press the
right
button on the  button keypad.
B.. Red LED on operator .
Red LED adjacent to operator power switch displays
blinking codes for:
Certain ln information
E error codes (Para. B.)
B.. Resetting error codes.
Options for resetting error codes:
. Set Mode switch in Close (off) position.
. User interface Reset buttons:
Press both left
and right buttons >s to reset
system.
Header cover must be opened to access user
interface.
. Power reset:
Turn power switch OFF.
Turn power switch back on after  seconds.
CAUTION
Always analyze and remove cause for error
before resetting error message!
Troubleshooting charts (Para. B.,.) are
intended as a guide for diagnosing errors.
TIPS AND RECOMMENDATIONS
Para. B.3, Information codes
Para. B.4, Error codes
> 3s Reset
< 3s Quit
> 3s
PRG
< 3s
LEARN
Fact-Setup
> 3s
> 8s
1
2
4
5
6
3
Close

Table of Contents

Other manuals for Dormakaba ED900

Related product manuals