132  Dover Fueling Solutions    W2940305    Rev 07    8/2019 
 
Code Erro
 Description
1  Flash program CRC error  Corrupted program data detected in POST (Power 
On Self Test) 
2  Flash template CRC error  Corrupted Template Data detected in POST 
3  RAM Error  RAM test failed.  The RAM test runs in POST and 
before the start of a sale. 
5  RAM error log CRC error  Corrupted RAM error log detected in POST 
6  RAM function programming CRC error  Corrupted RAM function data detected in POST 
7  RAM unit prices CRC error  Corrupted RAM unit price data detected in POST 
8  RAM statistics CRC error  Corrupted RAM statistics data detected in POST 
9  RAM event log CRC error  Corrupted RAM event log data detected in POST 
10  RAM totals CRC error  Corrupted RAM totals data detected in POST 
11  RAM totalizers CRC error  Corrupted RAM totalizer data detected in POST 
12  RAM Electro-mechanic totalizers CRC 
error 
Corrupted RAM EMT data detected in POST 
13  Identi-PROM CRC error-  
Device #0 = Display, Device #1 = CPU 
Identi-PROM data is only required for Ovation dual 
price posting displays and Century/Select displays. 
14  RAM Timestamps CRC error  Corrupted RAM timestamp data detected in POST 
16  Suppress overflow limit reached   This error is logged if overrun suppression is 
enabled (function 19.12 and 19.22) and the limit is 
exceeded) 
17  RAM meter data CRC error  Corrupt RAM meter Non-volatile data detected in 
POST 
18  RAM Door Security Data CRC Error  Corrupt RAM Door Security Data detected in 
POST 
20  n Consecutive display read back error- 
Device #s: 0=Sales, 1=Unit price, 
2=Preset 
Data which is sent to the displays is echoed back 
to verify connection and display board integrity.  
The data received from the display does not match 
the data sent.  The number of readback errors 
allowed is specified in function 17.02 
25  Sale cannot start-Zero Unit price  Unit price not set 
27  Sale cannot start-Unit price changed  Unit price has changed too close to the start of a 
sale.  The time is set/disabled through function 
23.04 
28  Sale cannot start-Need preset entry  Sales requires an entry from preset keypad if 
enabled in function 24.01 
30  No communications with POS timeout  Communication lost with POS for the amount of 
time specified in function 23.02 
31  POS buffer overflow (DART)  Communication error with POS 
34  Sale aborted because Stop Button pushed  Stop button signal was detected