132 Dover Fueling Solutions W2940305 Rev 07 8/2019
Code Erro
Description
1 Flash program CRC error Corrupted program data detected in POST (Power
On Self Test)
2 Flash template CRC error Corrupted Template Data detected in POST
3 RAM Error RAM test failed. The RAM test runs in POST and
before the start of a sale.
5 RAM error log CRC error Corrupted RAM error log detected in POST
6 RAM function programming CRC error Corrupted RAM function data detected in POST
7 RAM unit prices CRC error Corrupted RAM unit price data detected in POST
8 RAM statistics CRC error Corrupted RAM statistics data detected in POST
9 RAM event log CRC error Corrupted RAM event log data detected in POST
10 RAM totals CRC error Corrupted RAM totals data detected in POST
11 RAM totalizers CRC error Corrupted RAM totalizer data detected in POST
12 RAM Electro-mechanic totalizers CRC
error
Corrupted RAM EMT data detected in POST
13 Identi-PROM CRC error-
Device #0 = Display, Device #1 = CPU
Identi-PROM data is only required for Ovation dual
price posting displays and Century/Select displays.
14 RAM Timestamps CRC error Corrupted RAM timestamp data detected in POST
16 Suppress overflow limit reached This error is logged if overrun suppression is
enabled (function 19.12 and 19.22) and the limit is
exceeded)
17 RAM meter data CRC error Corrupt RAM meter Non-volatile data detected in
POST
18 RAM Door Security Data CRC Error Corrupt RAM Door Security Data detected in
POST
20 n Consecutive display read back error-
Device #s: 0=Sales, 1=Unit price,
2=Preset
Data which is sent to the displays is echoed back
to verify connection and display board integrity.
The data received from the display does not match
the data sent. The number of readback errors
allowed is specified in function 17.02
25 Sale cannot start-Zero Unit price Unit price not set
27 Sale cannot start-Unit price changed Unit price has changed too close to the start of a
sale. The time is set/disabled through function
23.04
28 Sale cannot start-Need preset entry Sales requires an entry from preset keypad if
enabled in function 24.01
30 No communications with POS timeout Communication lost with POS for the amount of
time specified in function 23.02
31 POS buffer overflow (DART) Communication error with POS
34 Sale aborted because Stop Button pushed Stop button signal was detected