W2940305 Rev 07 8/2019 Dover Fueling Solutions 133
Code Erro
r
Description
35 Blend ratio out of tolerance Total sale blend ratio exceeded the limits specified
in functions 7.02-7.04
39 Pulse output lags by more than 1 second Pulse output being sent to the POS was not able to
keep up with the sale flow rate
42 Vapor recovery motor on when it should
be off
Signal from the WayneVac system indicating that
the motor is turning when there is no fuel flow
43 Vapor recovery motor on when it should
be on
Signal from the WayneVac system indicating that
the motor is not turning when there is fuel flow
46 Vapor recovery motor turning wrong
direction
Feedback signals from the WayneVac system
indicate that the motor is turning in the wrong
direction
47 Illegal sensor states from vapor recovery
system
Feedback signals from the WayneVac system
indicate that the sensor signals are corrupted
48 Vapor recovery motor load high Amount of power required to run the WayneVac
motor has exceeded expected levels
49 Vapor recovery motor load low Amount of power required to run the WayneVac
motor is less than expected
50 Jitter/Reverse limit reached on an In
Transaction WIP
The meter has reported that amount of jitter pulses
during a sale has exceeded the number of pulses
specified in function 17.00
51 Jitter limit reached on an idle WIP The meter has reported that amount of jitter pulses
while the meter was idle has exceeded the number
of pulses specified in function 17.01
54 Reverse flow limit reached on idle WIP The meter has reported that amount of reverse
pulses while the meter was idle has exceeded the
number specified in function 16.03
56 Forward flow limit reached on an idle WIP The meter has reported that the amount of forward
pulses while the meter was idle has exceeded the
number specified in function 19.14/19.24
58 Communication lost to an In Transaction
WIP
Meter is not communicating with iGem. A
communication timeout occurred while the meter
was in use during a transaction
59 Communication lost to an idle WIP Meter is not communicating with iGem. A
communication timeout occurred while the meter
was idle
62 WIP is outputting jitter during calibration Volume exceeded expected limit during calibration
67 Meter calibration OK bit status changed Meter status changed from un-calibrated to
calibrated
68 Meter calibration door status changed Meter calibration door was closed
69 Meter last calibration status changed Meter last calibration indicated as successful
70 Timeout reached for No Flow Start of flow not detected for the amount of time as
specified in function 17.03
71 Consecutive No Flow timeouts Consecutive no flow errors have been detected for
the number of fillings specified in function 17.04
72 Timeout limit reached for flow lost during
sale
Flow was lost for the amount of time specified in
function 17.03
73 Consecutive Flow Lost timeouts Consecutive flow lost errors have been detected
for the number of fillings specified in function 17.05
74 Sale terminated before preset limit
reached
Sale did not reach preset limit set
75 Consecutive unfinished fillings Consecutive sales did not reach the preset limit.
Number of sales is specified in function 17.06
76 DEF Low Temperature Event DEF temperature change signal received; 1=Low
Temp, 2=Low Temp Cleared