134  Dover Fueling Solutions    W2940305    Rev 07    8/2019 
 
 
 
Code Erro
 Description
77 Additive Error 
Device #s: 
0=Config error 
1=CAN comm error 
2=Tank empty 
3=Tank door open 
4=Motor failure 
5=Injection fell short 
6=Flow error 
0=Additive config conflict 
1=No response from additive 
2=Tank reported empty 
3=Tank door reported open 
4=Additive motor not turning 
5=Additive injector not able to keep up w/ flowrate 
6=Additive flow not detected 
80  Software exception encountered 
0=Mail buffer pool exhausted 
1=Mail send failed 
2=XMalloc failed 
3=Print buffer overflow 
Internal iGEM board error indication 
90  Fuel temperature board communication 
failure 
iGEM has lost communication with the FTB, Fuel 
Temperature Board 
91  Fuel temperature board temperature probe 
shorted 
Defective or out of range probe detected by the 
FTB 
92  Fuel temperature board temperature probe 
shorted 
Defective or out of range probe detected by the 
FTB 
94  ATC configuration error  ATC function data programmed incorrectly 
95  Fuel Temp Board Calib error   
96  Dispenser security breached 
Device numbers: 
1=Bezel door 
2=Hydraulic door 
Door sensor switch activity detected while armed 
97  Dispenser security armed status change 
Device numbers: 
0=Dispenser unarmed 
1=Dispenser armed using One-Shot 
2+Dispenser armed using Maint Mode 
Date/Time that door security was armed/unarmed 
98  DEF errors, Device (D), Side (S)  DEF errors 
99  Hardware/Software mismatch – Device #s: 
0=No proportional hardware, 1=No vapor 
recovery hardware, 2=Meter does not 
match F16.04, 3=Ovation II not enough 
upd’s installed, 4=Ovation II too many 
upd’s installed 
Hardware configuration problem detected. 
Hardware signal is missing