DragonWave Inc. 76
Horizon Compact Release 1.01.00 Wireless Ethernet Product User Manual – Volume 2
Required Action Steps
set rls signal degrade
threshold [min degrade
threshold]
This option is the minimum percentage of the sample time which can
be used to record an error. The default value is 100. A setting of 100
(percent) means that the system will monitor for the full sample time,
even if enough errors are recorded to exceed the programmed error
rate. Decreasing the threshold allows the link to be shutdown faster
when higher block error rates are observed.
The default is "100", meaning 100% of the sample time.
Sequence:
set rls signal degrade threshold [min degrade threshold] press
Enter
Where
[minimum degrade threshold] is a percentage and sets the min
degrade threshold before link shut down. The threshold is a
percentage of the total [degrade time msec]
The system responds:
RLS link enable is set to [on/off]
set rls make rsl This is an optional command. This command sets the minimum RSL
value required to re-establish, or “make”, the link.
Sequence:
set rls make rsl [RSL (dB)] [Duration (sec)] press Enter
The system responds:
RLS Make RSL Parameters: [RSL (dB)] [Duration (sec)]
Example: set rls make rsl -60.0 100
When the RSL level is maintain at -60.0 or a higher value (less
negative) for the duration of the sample period (100 seconds), the link
will be re-established.
Setting the RSL sample period to zero (0), the default value, disables
this feature.