Advanced Configuration Features
77
Horizon Compact Release 1.01.00 Wireless Ethernet Product User Manual – Volume 2
Required Action Steps
set rls link monitor
parameters
This is a custom method for the configuration of the “soft error”
monitor. The method directly configures the sampling period, required
repeated consecutive samples and the errored block thresholds per
period of the “soft error” monitor. This method allows additional low-
level tuning of the “soft error” monitor.
Note: When this command is used, it overrides the set rls signal
degrade parameters and set rls signal degrade threshold
commands invoked by CLI, Web or SNMP methods.
Sequence:
set rls link monitor parameters [dn2up block errors per sample]
[up2dn block errors per sample] [dn2up # of samples] [up2dn # of
samples] [dn2up sample time in msec] [up2dn sample reset time
in msec]
Please contact DragonWave Customer Support for assistance if the
default “soft error” monitor behaviour needs to be tuned for a specific
application.
get rls signal fault parameters
The RLS signal fault settings are designed to detect and react to brief
bursts of extreme modem block error rates or link outages. The RLS
signal fault detection and reaction time is the quickest of the two RLS
fault detection methods. RLS signal fault detection works with the RLS
signal degrade settings in Advanced mode.
Sequence:
get rls signal fault parameters
The system responds:
RLS Signal Fault Parameters: 1000 100