41
Rx High Priority Packets: Number of Rx packets classified as high priority.
Rx Low Priority Packets: Number of Rx packets classified as low priority.
Rx Broadcast: Show the counting number of the received broadcast packet.
Rx Multicast: Show the counting number of the received multicast packet.
Tx Packets: The counting number of the packet transmitted.
TX Octets: Total transmitted bytes.
Tx High Priority Packets: Number of Tx packets classified as high priority.
Tx Low Priority Packets: Number of Tx packets classified as low priority.
Tx Broadcast: Show the counting number of the transmitted broadcast
packet.
Tx Multicast: Show the counting number of the transmitted multicast
packet.
Rx 64 Bytes:
Number of 64-byte frames in good and bad packets received.
Rx 65-127 Bytes: Number of 65 ~ 126-byte frames in good and bad packets
received.
Rx 128-255 Bytes: Number of 127 ~ 255-byte frames in good and bad packets
received.
Rx 256-511 Bytes: Number of 256 ~ 511-byte frames in good and bad packets
received.
Rx 512-1023 Bytes: Number of 512 ~ 1023-byte frames in good and bad packets
received.
Rx 1024-Bytes: Number of 1024-max_length-byte frames in good and bad
packets received.
Tx 64 Bytes: Number of 64-byte frames in good and bad packets
transmitted.
Tx 65-127 Bytes: Number of 65 ~ 126-byte frames in good and bad packets
transmitted.
Tx 128-255 Bytes: Number of 127 ~ 255-byte frames in good and bad packets
transmitted.
Tx 256-511 Bytes: Number of 256 ~ 511-byte frames in good and bad packets
transmitted.
Tx 512-1023 Bytes: Number of 512 ~ 1023-byte frames in good and bad packets
transmitted.
Tx 1024-Bytes: Number of 1024-max_length-byte frames in good and bad
packets transmitted.
Rx CRC/Alignment: Number of Alignment errors and CRC error packets
received.
Rx Undersize: Number of short frames (<64 Bytes) with valid CRC.
Rx Oversize: Number of long frames(according to max_length register)
with valid CRC.
Rx Fragments: Number of short frames (< 64 bytes) with invalid CRC.

Table of Contents

Other manuals for Draytek VigorSwitch G2080

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Draytek VigorSwitch G2080 and is the answer not in the manual?

Draytek VigorSwitch G2080 Specifications

General IconGeneral
BrandDraytek
ModelVigorSwitch G2080
CategorySwitch
LanguageEnglish

Related product manuals