Page #48 background imageLoading...
Page #48 background image
VigorSwitch G2080 User’s Guide
42
Rx Jabber: Number of long frames(according tomax_length register)
with invalid CRC.
Rx Drops: Frames dropped due to the lack of receiving buffer.
Rx Errors: Number of the error packet received.
Tx Collisions: Number of collisions transmitting frames experienced.
Tx Drops: Number of frames dropped due to excessive collision, late
collision, or frame aging.
Tx FIFO Drops: Number of frames dropped due to the lack of transmitting
buffer.
2
2
.
.
3
3
M
M
i
i
r
r
r
r
o
o
r
r
Function name:
Mirror Configuration
Function description:
Mirror Configuration is to monitor the traffic of the network. For example, we assume that
Port A and Port B are Monitoring Port and Monitored Port respectively, thus, the traffic
received by Port B will be copied to Port A for monitoring.
Note: When configuring the mirror function, you should avoid setting a port to be a
sniffer port and aggregated port at the same time. It will cause something wrong.
Parameter description:
Mode: Used for the activation or de-activation of Port Mirror
function. Default is Disable.
Monitoring Port: Set up the port for monitoring. Valid port is Port 1~8 and
default is
Port 1.
Monitored Port: Set up the port for being monitored. Just tick the check box
(;) beside the port x and valid port is Port 1~8.

Table of Contents

Other manuals for Draytek VigorSwitch G2080

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Draytek VigorSwitch G2080 and is the answer not in the manual?

Draytek VigorSwitch G2080 Specifications

General IconGeneral
BrandDraytek
ModelVigorSwitch G2080
CategorySwitch
LanguageEnglish

Related product manuals