D-3.1 Product Identifier AbCd
This parameter allows the user to define a four
digit alphanumeric product name to associate
with each product button.
The and keys are used to move through the
character set.
The and keys are used to move to the next
or previous character. The character that is
active will flash.
Hitting after the last character will take you to
the next parameter.
D-3.2 Cook Temperature Sett
This is the set-point temperature for the broiler
during this products cook cycle.
The product keys 1-8 are used for entering
numbers 1-8. The and keys are used to
enter numbers 0 and 9.
D-3.3 Cooking Profile on 1, oFF1, on 2,
oFF2,
Defines the cycling parameters for the upper
infrared burner and the overall cook time.
These parameters will have 6 segments. Each
segment consists of one On/Off cycle.
The On portion of the cycle will come first.
The product keys 1-8 are used for entering
numbers 1-8. The and keys are used to
enter numbers 0 and 9.
The control will display the total cook time (the
sum of all ON and OFF cycles) as a final non-
changeable parameter.
As an example:
After entering this last parameter; Hitting the
key will take you back to the Product selection, so
that you can select another product to program.
D-3.4 Exit Program Mode
To exit programming and save new entries press
the ENTER key until the control displays RdY,
PrE or Lo.
To exit programming without saving entries,
cycle the main On/Off switch off and on.
D-4.0 Level 2 Programming
Enter the password 3-6-4-5 and press the
ENTER key.
D-4.1 ºF or ºC Parameter dEg
Changes temperature displayed between
Fahrenheit (F) and Celsius (C).
The and keys are used scroll through the
settings.
D-4.2 Change the Idle Temperature Sett
This is the set-point temperature for the broiler
during the preheat and idle cycles.
The default for this parameter is 680 ºF.
The product keys 1-8 are used for entering
numbers 1-8. The and keys are used to
enter numbers 0 and 9.
D-4.3 Additional Factory Parameters
The remaining parameters in this section are
factory settings and should not be changed.
These settings are as follows:
oFSt
Hton
Lo t
Hi t
Cdti
BEEP
IrSt
PCr
AFCr
D-4.4 Exit Program Mode
To exit programming and save new entries press
the ENTER key until the control displays RdY,
PrE or Lo.
To exit programming without saving entries,
cycle the main On/Off switch off and on.