Before You Start/Safety Guidelines AS9216 Installation and
Maintenance Manual
1-2 ECI Telecom Ltd. Proprietary 492006-2306-013-A00
WARNING: GROUNDING
Before connecting the product to the power line, make sure
that the protective ground terminal of the device is
connected to the safety ground conductor of the mains
power cord.
The main power supply plug should only be inserted in a
socket outlet provided with a connected safety ground. The
protective action must not be negated by use of an
extension cord (power cable) without a protective
conductor (grounding). Any interruption of the protective
(grounding) conductor or disconnection of the protective
ground terminal can make the device unsafe to use.
Intentional interruption is prohibited.
This equipment has a connection between the earthed
conductor of the DC supply circuit and the grounding
conductor.
WARNING: LINE VOLTAGE
Before connecting the product to the power line, make sure
the voltage of the power source matches the requirements
of the product, as marked on the label located near the
power connectors.
WARNING: DC POWER SOURCE
The DC power source should be protected with a branch
circuit over-current protection rated at 15Amp, located in
the building installation
WARNING: BUNDLED POWER SUPPLY CABLE
A bundled power supply cable is supplied with this
product. This cable must be used exclusively with this
product. Do not use any other power supply cable with this
product. Do not use this power supply cable with any other
product.