EasyManuals Logo

ECI AS9216 User Manual

Default Icon
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
Using the Command Line Interface
(CLI)
AS9216 Installation and
Maintenance Manual
8-6 ECI Telecom Ltd. Proprietary 492006-2306-013-A00
Using the CLI
Command Keywords and Arguments
A CLI command is built up of a series of keywords and arguments:
Keywords identify the command’s action
Arguments specify the command’s configuration parameters
The CLI commands are not case sensitive.
The general CLI syntax is represented by the following format:
device-name[(config- ...)]#keyword(s) [argument(s)] ...
[keyword(s)] [argument(s)]
In this format
device-name[(config ...)]# represents the prompt displayed by the device.
This prompt includes:
the user-defined device-name
the current CLI mode
the command keywords and arguments typed by the user
Example:
In the command below:
device-name(config-port-1/1/10)#description access
the CLI mode is config-port-1/1/10
description is the command keyword
access is the command argument

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ECI AS9216 and is the answer not in the manual?

ECI AS9216 Specifications

General IconGeneral
BrandECI
ModelAS9216
CategorySwitch
LanguageEnglish