INSTRUCTIONS MANUAL
-76-
Procure a bottle of appropriate refrigerant (R134a or R1234yf depending on machine model),
connect and open LP or HP coupler to the liquid side of the external bottle and open the liquid
valve, then press . The BOTTLE FILLING will start
the machine will now fill the machine tank with the preset quantity ~ 500g. When the quantity
minus 500 grams is reached, the machine will stop and display:
Close the liquid valve of the external bottle and press , the machine will recover the residual
refrigerant from the hoses, then will display the following screen:
Close and disconnect LP coupling from external bottle and press .Bottle filling procedure
successfully completed. Switch the machine off.
NOTE: if the external bottle is not supplied with a liquid side coupling, upend it to recover liquid
refrigerant.
DD/MM/YY XX:XX PM
MAINTENANCE / TANK FILLING
Connect and open LP or HP coupler to the liquid side
of the external bottle and open the liquid valve.
Then press to continue
DD/MM/YY XX:XX PM
MAINTENANCE / TANK FILLING
Disconnect LP or HP coupler
to the side of external bottle
DD/MM/YY XX:XX PM
MAINTENANCE / TANK FILLING
Disconnect LP or HP coupler
to the side of external bottle
DD/MM/YY XX:XX PM
Refrigerant charged
14g / (2%)
External tank pressure
0.86 bar
Tank filling
MAINTENANCE / TANK FILLING
Tank pressure
5.71 bar