EasyManua.ls Logo

Ecotechnics ECK FLAG - VACUUM PUMP MAINTENANCE; VACUUM PUMP OIL PROCEDURES; M.1) OIL TOP-UP PROCEDURE

Default Icon
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTRUCTIONS MANUAL
-89-
3
MAX
MIN
FIG.
18
TOOLS:
Funn
el
Disp
osal
conta
iner
Allen
wren
ch n°
5; 8.
5
1
The oil must be added through the hole in which the oil cap was lodged by using a proper
funnel (ref 5, Fig.18).
Add oil a little at a time, waiting for the level to rise before each successive addition, until the oil
level is about ½ cm above the red mark on the indicator (ref 3, Fig.18).
Replace the filling cap (ref 1, Fig.18) and tighten down.

Table of Contents