EasyManua.ls Logo

Electrolux EWM1000 - EWM1000 plus, EWM2000 EVO, EWM3000 NEW Alarm Codes

Electrolux EWM1000
176 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EWM1000plus EWM2000evo EWM3000new
QUICK GUIDE AND APPLIANCES LIST 27/176 599 72 40-80
2.11 Table of alarms codes EWM 1000plus EWM2000EVO EWM3000NEW
Alarm Description Possible malfunction Action/status of machine Reset
E00
No alarm ---
E11 Poor water fill before wash cycle
Tap closed or water pressure too low; Drain tube improperly positioned;
Water fill solenoid valve is defective; Leaks from water circuit on
pressure switch; Pressure switch defective; Wiring defective; Main board
defective.
Cycle is paused with door locked Start
E12
Difficulty in water fill during drying (maximum
time 3 min. water fill in drying during the wash
load unrolling phase)
Tap closed or water pressure too low; solenoid valve; pressure switch
water circuit; pressure switches; wiring; main board.
Cycle is paused Start
E13 Water leaks
Drain tube improperly positioned; Water pressure too low;
Water fill solenoid valve is defective; Water circuit on pressure switch is
leaking/clogged; Pressure switch defective.
Cycle is paused with door locked Start
E21 Poor draining
Drain tube kinked/clogged/improperly positioned; Drain filter
clogged/dirty; Drain pump defective; Pressure switch defective; Wiring
defective; Main board defective; Electrical current leak between heating
element and ground.
Cycle is paused Start
E22
Difficulty in water fill during drying or drying
condenser clogged (anti-boiling pressure
switch closed on “FULL”)
Drain hose kinked; filter clogged: drying condenser clogged; drain pump
faulty; pressure switches faulty; wiring; main circuit board defective;
current leakage between heater and ground.
Cycle is paused Start
E23
Defective triac for drain pump Drain pump defective; Wiring defective; Main board defective.
Emergency drain procedure - Cycle
stops with door unlocked
OFF/reset
E24
Malfunction in sensing circuit on triac for drain
pump
Main board defective.
Emergency drain procedure - Cycle
stops with door unlocked
OFF/reset
E31
Malfunction in pressure switch circuit
(frequency of signal from pressure switch out
of limits)
Pressure switch; Wiring; Main board; Cycle stops with door locked OFF/reset
E32
Electronic pressure switch improperly
calibrated (level on electronic pressure switch
differs from 0-66 mm after initial calibration
drain and when antiboiling pressure switch is
on “empty”).
Tap is closed or water pressure is too low;
Solenoid valve;
Water circuit on pressure switches; pressure switches;
Wiring; main board;
Cycle is paused Start
E33
Inconsistency between level on electronic
pressure switch and level on antiboiling
pressure switch 1-2 (fault persists for at least
60 sec.).
Pressure switch defective;
Electrical current leak between heating element and ground; Heating
element; Wiring defective;
Main board defective.
Water circuit;
Emergency drain procedure - Cycle
stops with door unlocked
OFF/reset
E34
Inconsistency between level on electronic
pressure switch and level on antiboiling
pressure switch 2 (fault persists for at least 60
sec.).
Pressure switch defective;
Electrical current leak between heating element and ground; Heating
element; Wiring defective;
Main board defective.
Water circuit;
Emergency drain procedure - Cycle
stops with door unlocked
OFF/reset

Table of Contents