EWM1000plus EWM2000evo EWM3000new
QUICK GUIDE AND APPLIANCES LIST 27/176 599 72 40-80
2.11 Table of alarms codes EWM 1000plus EWM2000EVO EWM3000NEW
Alarm Description Possible malfunction Action/status of machine Reset
E00
No alarm ---
E11 Poor water fill before wash cycle
Tap closed or water pressure too low; Drain tube improperly positioned;
Water fill solenoid valve is defective; Leaks from water circuit on
pressure switch; Pressure switch defective; Wiring defective; Main board
defective.
Cycle is paused with door locked Start
E12
Difficulty in water fill during drying (maximum
time 3 min. water fill in drying during the wash
load unrolling phase)
Tap closed or water pressure too low; solenoid valve; pressure switch
water circuit; pressure switches; wiring; main board.
Cycle is paused Start
E13 Water leaks
Drain tube improperly positioned; Water pressure too low;
Water fill solenoid valve is defective; Water circuit on pressure switch is
leaking/clogged; Pressure switch defective.
Cycle is paused with door locked Start
E21 Poor draining
Drain tube kinked/clogged/improperly positioned; Drain filter
clogged/dirty; Drain pump defective; Pressure switch defective; Wiring
defective; Main board defective; Electrical current leak between heating
element and ground.
Cycle is paused Start
E22
Difficulty in water fill during drying or drying
condenser clogged (anti-boiling pressure
switch closed on “FULL”)
Drain hose kinked; filter clogged: drying condenser clogged; drain pump
faulty; pressure switches faulty; wiring; main circuit board defective;
current leakage between heater and ground.
Cycle is paused Start
E23
Defective triac for drain pump Drain pump defective; Wiring defective; Main board defective.
Emergency drain procedure - Cycle
stops with door unlocked
OFF/reset
E24
Malfunction in sensing circuit on triac for drain
pump
Main board defective.
Emergency drain procedure - Cycle
stops with door unlocked
OFF/reset
E31
Malfunction in pressure switch circuit
(frequency of signal from pressure switch out
of limits)
Pressure switch; Wiring; Main board; Cycle stops with door locked OFF/reset
E32
Electronic pressure switch improperly
calibrated (level on electronic pressure switch
differs from 0-66 mm after initial calibration
drain and when antiboiling pressure switch is
on “empty”).
Tap is closed or water pressure is too low;
Solenoid valve;
Water circuit on pressure switches; pressure switches;
Wiring; main board;
Cycle is paused Start
E33
Inconsistency between level on electronic
pressure switch and level on antiboiling
pressure switch 1-2 (fault persists for at least
60 sec.).
Pressure switch defective;
Electrical current leak between heating element and ground; Heating
element; Wiring defective;
Main board defective.
Water circuit;
Emergency drain procedure - Cycle
stops with door unlocked
OFF/reset
E34
Inconsistency between level on electronic
pressure switch and level on antiboiling
pressure switch 2 (fault persists for at least 60
sec.).
Pressure switch defective;
Electrical current leak between heating element and ground; Heating
element; Wiring defective;
Main board defective.
Water circuit;
Emergency drain procedure - Cycle
stops with door unlocked
OFF/reset