1.6 Table of alarms codes EWM1000
Alarm Description Possible fault Action/Machine status Reset
E00
No alarm
E11 Difficulty in filling during wash phase
Tap closed or water pressure insufficient; Drain hose
incorrectly positioned; Water fill solenoid faulty; Leaks from
pressure switch hydraulic circuit; Pressure switch faulty;
Wiring faulty; Circuit board faulty.
Cycle paused, door closed Start
E13 Water leakage
Drain hose incorrectly positioned; Water pressure
insufficient; Water fill solenoid faulty; Leaks or blockage in
pressure switch hydraulic circuit; Pressure switch faulty;
Circuit board faulty.
Cycle paused, door closed Start
E21 Difficulties in draining
Drain hose kinked/blocked/incorrectly positioned; Drain filter
clogged or dirty; Drain pump faulty; Pressure switch faulty;
Wiring faulty; Circuit board faulty; Current leakage from
heating element to ground.
Cycle paused Start
E23
Drain pump triac faulty Drain pump faulty; Wiring faulty; Circuit board faulty. Safety drain - Cycle stopped, door open Selector on “0”
E24
Problems with «sensing» of drain pump triac Circuit board faulty. Safety drain – Cycle stopped, door released Selector on “0”
E33
Incongruence between contact closure of anti-
boiling and 1st level of pressure switch
Pressure switch faulty; Current leakage from heating
element to ground; Heating element; Wiring faulty; Circuit
board faulty.
Safety drain - Cycle stopped, door open Selector on “0”
E35 Water overflow
Water fill solenoid faulty; Leaks from pressure switch
hydraulic circuit; Pressure switch faulty; Wiring faulty; Circuit
board faulty.
Cycle blocked, door closed. Safety drain.
Drain pump (sequence 5 min. ON - 5 min.
OFF)
Selector on “0”
E36
«sensing» circuit of anti-boiling pressure switch
faulty
Circuit board faulty. Cycle blocked, door closed Selector on “0”
E37
«sensing» circuit of 1st level faulty Circuit board faulty. Cycle blocked, door closed Selector on “0”
E39
HV «sensing» circuit of anti-flooding pressure
switch faulty
Circuit board faulty. Cycle blocked, door closed Selector on “0”
E41
Door open
Door safety interlock faulty; Wiring faulty;
Circuit board faulty.
Cycle paused Start
E42
Problems with aperture of door
Door safety interlock faulty; Wiring faulty;
Circuit board faulty
Cycle paused
Start or Selector
on “0”
E43
Power triac on door interlock faulty
Door safety interlock faulty; Wiring faulty;
Circuit board faulty.
Safety drain, door released Selector on “0”
E44
Door interlock «sensing» faulty Circuit board faulty. Safety drain, door released Selector on “0”
E45
«sensing» on door interlock triac faulty Circuit board faulty. Safety drain, door released Selector on “0”
E51
Motor power triac short-circuited
Circuit board faulty;
Current leakage from motor or wiring.
Cycle blocked, door closed (after 5 attempts in
diagnostics or immediate during selection)
Selector on “0”
E52 No signal from motor tachimetric generator
Motor faulty; Wiring faulty;
Circuit board faulty.
Cycle blocked, door closed (after 5 attempts in
diagnostics or immediate during selection)
Selector on “0”
E53
«sensing» circuit on motor triac faulty Circuit board faulty. Cycle blocked Selector on “0