ENV06 EWM11xx EWM21xx EWM25xx/35xx
QUICK GUIDE AND APPLIANCES LIST 49/176 599 72 40-80
Alarm Possible fault Action/machine status Reset Alarm
EF1
Drain filter blocked
(drain phase too long)
Drain tube blocked/kinked/too high;
Drain filter dirty/blocked.
Warning displayed at the end of cycle
(specific LED).
START/RESET
EF2
Excessive detergent dosing
(excessive foam during draining)
Excessive detergent dosing; drain tube kinked/blocked;
Drain filter dirty/blocked.
Warning displayed after 5 attempts or
by the specific LED.
RESET
EF3
Aqua control intervention Water leaks onto base frame; water control system defective. Water drain.
ON/OFF
RESET
EF4
Water fill pressure low, no signal of
flowmeter and solenoid valve open
Tap closed; water fill pressure low. ---------------- RESET
EF5
Unbalanced load Final spin phases skipped. ---------------- RESET
EF6
Reset ----------------
No action to be performed, if continues
replace the PCB.
----------------
EH1
Frequency power of appliance out of
limits
Power supply problems (incorrect / disturbance); PCB faulty. Wait for frequency nominal conditions. OFF/ON
EH2
Voltage too high Power supply problems (incorrect / disturbance); PCB faulty. Wait for frequency nominal conditions. OFF/ON
EH3
Voltage too low Power supply problems (incorrect / disturbance); PCB faulty. Wait for frequency nominal conditions. OFF/ON
EHE
Incongruence between safety relay (in the
PCB) and the safety “sensing” circuit
Wiring faulty; PCB faulty.
Safety drain cycle – Cycle stopped
with door open.
RESET
EHF
Safety “sensing” circuit faulty (input
voltage to microprocessor wrong)
PCB faulty.
Safety drain cycle – Cycle stopped
with door open.
RESET
3.5.1 Notes concerning certain alarm codes
Configuration alarms E93: If this alarm is generated (when the appliance is switched on), operation of the appliance is blocked, the LEDs placed above or inside the
START/PAUSE button start to flash displaying the complete codification (family plus alarm), the display shows the alarm code on condition that the configuration part of the
display is ok.
The diagnostic procedure cannot be accessed; the only option is to switch the appliance OFF.
Configuration alarm E94: all LEDs placed above or inside the START/PAUSE button start to flash displaying the complete codification (family plus alarm) and the code is
displayed.
It is not possible to enter the diagnostics or to use the mode “rapid displaying of the alarm”.
Alarms EH1(Eb1)-EH2(Eb2)-EH3(Eb3): In the event of problems with the mains power supply, the appliance remains in alarm mode until the mains frequency or voltage are
restored to the correct value or the appliance is switched off (programme selector on “0”). The family of alarm “b or H” only is displayed if the problem occurs during the normal
operation of the appliance, while the family plus the alarm are displayed if the problem occurs at the switching on, through the flashing of the LEDs placed above or inside the
START/PAUSE button. At the same time the code is represented also in the display.
It is not possible to enter the diagnostics or to use the mode “rapid displaying of the alarm”: the complete alarm can be read only when the abnormal situation has terminated.
Alarms E51- E52: During the diagnostic test, all the alarms are displayed. Normally, when the programme selector is turned from one test phase to another, the appliance exits the
alarm condition and performs the phase selected. This does not take place in the case of alarms E51 (power triac on motor short-circuited) and E52 (no signal from the tachometric
generator on the motor): in these cases, the only option to exit the alarm condition is to switch the appliance OFF by turning the selector to position “0” (reset) or pushing the ON/OFF
button (INPUT styling).