ENV06 EWM11xx EWM21xx EWM25xx/35xx
QUICK GUIDE AND APPLIANCES LIST 46/176 599 72 40-80
3.5 Table of alarms codes ENV06
Alarm Possible fault Action/machine status Reset Alarm
E00
No alarm
E11 Difficulties in water fill for washing
Tap closed or water pressure too low; Drain tube improperly positioned; Water
fill solenoid valve is faulty; Leaks from water circuit on pressure switch;
Pressure switch faulty; Wiring faulty; PCB faulty.
Cycle is paused with door locked. START/RESET
E12 Difficulties in water fill for drying
Tap closed or water pressure too low; Drain tube improperly positioned; Water
fill solenoid valve is faulty; Leaks from water circuit on pressure switch;
Pressure switch faulty; Wiring faulty; PCB faulty.
Cycle is paused with door locked. START/RESET
E13 Water leakage
Drain hose incorrectly positioned; mains pressure insufficient; water fill solenoid
faulty; leakage/blockage of pressure switch hydraulic circuit; pressure switch
faulty.
Cycle is paused with door locked. START/RESET
E21
Difficulties in draining for washing
Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain
pump faulty; Pressure switch faulty; Wiring faulty; PCB faulty.
Cycle is paused (after 2 attempts). START/RESET
E22
Difficulties in draining for drying
Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain
pump faulty; Pressure switch faulty; Wiring faulty; PCB faulty.
Cycle is paused. START/RESET
E23
Drain pump triac faulty Drain pump faulty; Wiring faulty; PCB faulty.
Safety drain cycle - Cycle stops with
door unlocked.
RESET
E24
Fault in “sensing” circuit of drain pump
triac (wrong input signal to
microprocessor)
PCB faulty.
Safety drain cycle - Cycle stops with
door unlocked.
RESET
E31
Electronic pressure switch circuit faulty
(frequency of pressure switch signal out
of limits)
Electronic pressure switch; Wiring; PCB faulty. Cycle blocked with door closed. RESET
E32
Incorrect calibration of electronic
pressure switch
(The electronic pressure switch generates
a signal with instable frequency during
the drain phase)
Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain
pump faulty;
Leaks from water circuit on pressure switch; Pressure switch;
Wiring faulty; PCB faulty.
Cycle is paused. START/RESET
E35
Water overflow
Water fill solenoid faulty; Leaks from water circuit on pressure switch; pressure
switch faulty; wiring faulty; PCB faulty.
Cycle blocked. Safety drain cycle.
Drain pump always in operation (5
minutes on, 5 minutes off etc.).
RESET
E38
Pressure chamber blocked
(water level does not vary for at least 30
sec. during drum rotation
Motor drive belt broken; Hydraulic circuit pressure switch clogged. Heating phase skipped.
ON/OFF
RESET
E3A
Heating elem. relay sensing faulty
(input signal to microprocessor always 0
or 5V)
PCB faulty. Cycle blocked with door closed. RESET
E41
Door open (after 15 sec.) Door interlock faulty; wiring faulty; PCB faulty. Cycle paused. START/RESET
E42
Problems of door closure Door interlock faulty; wiring faulty; PCB faulty. Cycle paused. START/RESET
E43
Interlock power supply triac faulty Door interlock faulty; wiring faulty; PCB faulty. (Safety drain cycle) Cycle blocked.
ON/OFF
RESET