ENV06 EWM11xx EWM21xx EWM25xx/35xx
QUICK GUIDE AND APPLIANCES LIST 47/176 599 72 40-80
Alarm Possible fault Action/machine status Reset Alarm
E44
Door interlock sensing circuit triac faulty PCB faulty. (Safety drain cycle) Cycle blocked.
ON/OFF
RESET
E45
Door interlock sensing circuit triac faulty
(wrong input signal to microprocessor)
PCB faulty. (Safety drain cycle) Cycle blocked.
ON/OFF
RESET
E52
No signal from motor tachometric
generator
Motor faulty; wiring faulty; PCB faulty.
Cycle blocked, door locked (after 5
attempts).
RESET
E57
Inverter is drawing too much current
(
>15A)
Motor-Inverter wiring faulty; Inverter board faulty, Motor faulty.
Cycle blocked, door locked (after 5
attempts).
RESET
E58
Inverter is drawing too much current
(
>4,5A)
Motor abnormal operation (overloaded); Motor-Inverter wiring faulty; Motor
faulty; Inverter board faulty.
Cycle blocked, door locked (after 5
attempts).
RESET
E59
No signal from tachometric generator for
three seconds
Motor-Inverter wiring faulty; Inverter board faulty, Motor faulty.
Cycle blocked, door locked (after 5
attempts).
RESET
E5A
Overheating for heat dissipator for
Inverter
Overheating caused by continuous operation or ambient conditions (let
appliance cool down); Inverter board faulty. NTC open (on the Inverter board).
Cycle blocked, door locked (after 5
attempts).
RESET
E5H
Input voltage is lower than 175V Wiring faulty; Inverter board faulty.
Cycle blocked, door locked (after 5
attempts).
RESET
E5C
Input voltage is too high Input voltage is too high (measure the masters voltage); Inverter board faulty.
Cycle blocked, door locked (after 5
attempts).
RESET
E5d
Data transfer error between Inverter and
main board
Line interference; Wiring faulty; Main board or Inverter faulty. ---------------- RESET
E5E
Wrong communication between main
board and Inverter
Main board-Inverter wiring faulty; Inverter board faulty; Main board faulty. Cycle blocked (after 5 attempts). ON/OFF
E5F
Inverter board does not start the motor Wiring faulty; Inverter board faulty; Main board faulty.
Cycle blocked, door locked (after 5
attempts).
RESET
E61
Insufficient heating during washing NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty. The heating phase is skipped. START/RESET
E62
Overheating during washing (temperature
higher than 88°C for a time higher than 5
min.)
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty.
Safety drain cycle – Cycle stopped
with door open.
RESET
E66
Heating element power relay faulty
(incongruence between sensing and
relay)
PCB faulty.
Safety drain cycle – Cycle stopped
with door open.
RESET
E68
Current dispersion to earth (value of
mains voltage different from main value)
Current dispersion between between heating element and earth. Cycle blocked with door open. RESET
E69
Heating element interrupted Wiring faulty; Heating element for washing interrupted (thermofuse open). ---------------- START/RESET
E71
Washing NTC sensor faulty (short-
circuited or open)
Wiring faulty; Washing NTC sensor faulty; PCB faulty. The heating phase is skipped. START/RESET
E72
Drying condenser NTC sensor faulty
(voltage value out of limits, sensor short-
circuited or open)
Wiring faulty; Drying NTC sensor (condenser) badly positioned or faulty; WD
board faulty.
The drying heating phase is skipped. START/RESET
E73
Drying duct NTC sensor faulty (voltage
value out of limits, sensor short-circuited
or open)
Wiring faulty; Drying NTC sensor (duct) badly positioned or faulty; WD board
faulty.
The drying heating phase is skipped. START/RESET
E74
Washing NTC sensor badly positioned
Wiring faulty; Washing NTC sensor badly positioned; NTC sensor faulty; PCB
faulty.
The heating phase is skipped. START/RESET