QUICK GUIDE AND APPLIANCES LIST 29/176 599 72 40-80
Alarm Description Possible malfunction Action/status of machine Reset
E5E
Communication error between inverter and
main board
Defective wiring between main board and inverter board,
Defective inverter board, defective main board
Cycle stops OFF
E5F
Inverter board fails to start the motor Defective inverter board, Defective wiring, defective main board
Cycle stops with door locked (after 5
attempts).
OFF/reset
E61 Insufficient heating during wash cycle
Defective NTC sensor for wash cycle; Heating element defective; Wiring
defective; Main board defective.
Heating phase is skipped Start
E62
Overheating during wash cycle
Defective NTC sensor for wash cycle; Heating element defective; Wiring
defective; Main board defective.
Safety drain cycle - Cycle stops with door
unlocked
OFF/reset
E66
Relay supplying power to heating element
defective
Main board defective; Electrical current leak from heating element to
ground.
Safety drain cycle - Cycle stops with door
unlocked
OFF/reset
E71 NTC sensor for wash cycle defective
Defective NTC sensor; Wiring defective;
Main board defective.
Heating is skipped Start
E72
Fault in NTC sensor on drying condenser
(voltage out of range = short-circuit, open
circuit)
Drying NTC sensor (condenser) defective; wiring defective; main circuit
board defective.
Heating is skipped Start
E73
Fault in NTC sensor on drying duct (voltage
out of range = short-circuit, open circuit)
Drying NTC sensor (duct) defective; wiring defective; main circuit board
defective.
Heating is skipped Start
E74
NTC sensor for wash cycle improperly
positioned
NTC sensor improperly positioned; Defective NTC sensor; Wiring
defective; Main board defective.
Heating is skipped Start
E82
Error in selector reset position PCB faulty (Wrong configuration data). Selector, wiring --- OFF/reset
E83
Error in reading selector PCB faulty (Wrong configuration data). Selector, wiring Cycle cancelled ---
E84
Recirculation pump defective (inconsistency
between the state of the sensing circuit for the
recirculation pump and the state of the triac)
Recirculation pump;
Wiring;
Main board;
Machine drains and cycle stops (with
door unlocked)
OFF/reset
E85
Defective sensing circuit on triac for
recirculation pump (input voltage on
microprocessor remains at 0 or 5 V).
Main board
Machine drains and cycle stops (with
door unlocked)
OFF/reset
E91
Communication error between main board and
display board
Wiring defective; Control/display board defective
Main board defective.
Cycle stops ---
E92
Inconsistency in communication between main
board and display board
(versions not compatible)
Wrong control/display board;
Wrong main board (not right for model).
Cycle stops ---
E93
Configuration error on appliance Main board defective (Improper programming). Cycle stops OFF/reset
E94
Configuration error on wash cycle Main board defective (Improper programming). Cycle stops OFF/reset
E95
Communication error between microprocessor
and EEPROM
Main board defective. Cycle stops OFF/reset
E97
Inconsistency between list of programmes and
configuration of cycle
Main board defective (Improper programming). Cycle stops OFF/reset
E98
Communication error between microprocessor
and clock
Display board faulty The cycle continues -----------
EB1
Frequency of power supplied to appliance out
of limits
Problems with the power mains (wrong power/interference); Main board
defective.
Cycle stops ---